STOCKTROL

» Sales Brochure STOCKTROL (PDF)

The STOCKTROL is available in 4 different models:

A special model SEDIMENT for interface detection, (e.g. sand in water), is available for all types

The qualities of the STOCKTROL are convincing:


STOCKTROL CV210: standard model

Insertion length: approx. 190mm
Mounting position: top or side
Process connection: Thread 1-1/2"EN10226 (DIN2999=BSPT) or NPT
Power supply: Wide range 20...250V AC/DC
with relay output DPDT
or: 24V-DC with transistor output NPN or PNP (3-wire)
or: 20...30V-DC with 8/16mA current output (2-wire)
for supply and output conversion we recommend our analyzing unit CV2000AE
Approvals: Dust-Ex:ATEX II 1/2D for zones 20/21
Gas-Ex: ATEX II 1G Ex ia IIB T4 for zone 0
for supply and output conversion the associated apparatus CV2000AE[Exi] has to be used
» Sales Brochure STOCKTROL (PDF)


STOCKTROL CV310: with welded pipe extension

Insertion length: min. 290mm
max. 2.000mm
Mounting position: top mounting, side mounting possible for short extensions
Process connection: Thread 1-1/2"EN10226 (DIN2999=BSPT) or NPT
alternatively: Tri-Clamp for food applications
Power supply: Wide range 20...250V AC/DC
with relay output DPDT
or: 24V-DC with transistor output NPN or PNP (3-wire)
or: 20...30V-DC with 8/16mA current output (2-wire)
for supply and output conversion we recommend our analyzing unit CV2000AE
Approvals: Dust-Ex:ATEX II 1/2D for zones 20/21
Gas-Ex: ATEX II 1G Ex ia IIB T4 for zone 0
for supply and output conversion the associated apparatus CV2000AE[Exi] has to be used
»Sales Brochure STOCKTROL (PDF)


STOCKTROL CV410: with threaded pipe extension

Insertion length: min. 350mm
max. 4.000mm
Mounting position: top mounting, side mounting possible for short extensions
Process connection: Thread 1-1/2" (DIN2999=BSPT) or NPT
Power supply: Wide range 20...250V AC/DC
with relay output DPDT
or: 24V-DC with transistor output NPN or PNP (3-wire)
or: 20...30V-DC with 8/16mA current output (2-wire)
for supply and output conversion we recommend our analyzing unit CV2000AE
» Sales Brochure STOCKTROL (PDF)



STOCKTROL CV510: model with cable extension

Insertion length: min. 410mm
max. 20.000mm
Mounting position: top mounting
Process connection: Thread 1-1/2"EN10226 (DIN2999=BSPT) or NPT
Power supply: Wide range 20...250V AC/DC
with relay output DPDT
or: 24V-DC with transistor output NPN or PNP (3-wire)
or: 20...30V-DC with 8/16mA current output (2-wire)
for supply and output conversion we recommend our analyzing unit CV2000AE
Approvals: Dust-Ex:ATEX II 1/2D for zones 20/21
Gas-Ex: ATEX II 1G Ex ia IIB T4 for zone 0
for supply and output conversion the associated apparatus CV2000AE[Exi] has to be used
»Sales Brochure STOCKTROL (PDF)
» Deutsch
PTL Hermann Kopfbild
PTL Hermann GmbH | Kellermatten 3 | D-79618 Rheinfelden-Eichsel/Germany | Tel:+49-(0)-7623-747954 | Fax:+49-(0)-7623-47589